Anaerobic high temperature test chamber


Retail price

Market price


Anaerobic high temperature test chamber

key word:humidity

Consultation hotline:

weight

Quantity
-
+

inventory

隐藏域元素占位

  • Advisory Details
  • Product name

    Anaerobic high temperature test chamber

    Model

    YY91-200 YY216-200 YY512-200 YY1000-200 YY91-300 YY216-300 YY512-300 YY1000-300

    Interior volume (L)

    91 216 512 1000 91 216 512 1000

    Inside dimension

    (mm)

    W

    450 600 800 1000 450 600 800 1000

    H

    450 600 800 1000 450 600 800 1000

    D

    450 600 800 1000 450 600 800 1000

    Outside dimension (mm)

    W

    1060 1210 1500 1730 1060 1210 1500 1730

    H

    820 970 1210 1480 820 970 1210 1480

    D

    635 785 1065 1270 635 785 1065 1270
    Temperature range (℃) (ambient temperature+20~200)℃ (ambient temperature+20~300)℃
    Heating and cooling time (min) (ambient temperature+20~200)℃ (ambient temperature+20~300)℃
    ≤40/min ≤60/min ≤70/min
    Residual oxygen concentration<100ppm, flow rate of pure inert gas (such as N2) consumed ≤ 20L/min (reduced to ≤ 50min) ≤ 50L/min (reduced to ≤ 50min) ≤ 100L/min (reduced to ≤ 50min) ≤ 200L/min (reduced to ≤ 50min)
    ≤ 7L/min (concentration maintained) ≤ 15L/min (concentration maintained) ≤ 30L/min (concentration maintained) ≤ 60L/min (concentration maintained)
    Temperature regulation method Forced air circulation heat exchange method+internal cooling system
    Usage environment Temperature: (5~36) ℃ Humidity: (30~85)%RH Air pressure: (86~106) kPa
    Material Science

    Inner box

    Stainless steel plate SUS304

    Outer box

    Double sided galvanized sheet, surface treated with electrostatic spraying treatment
    Heat preservation

    Fiber high-temperature cotton+polyurethane foam

    Box door sealing strip High temperature resistant sealing strip (excluding silicon)
    Actuator

    Fan

    Extended shaft centrifugal fan

    Damper

    Manually adjust ventilation and circulation

    Heater

    Imported nickel chromium alloy electric heating wire
    Controller system

    Display screen+PLC

    7.0", 800x480 resolution, mixed output PLC

    Operation mode

    Program execution

    Setting method

    Simplified Chinese+English, touch input

    Display resolution

    Temperature: 0.1 ℃, Time: s

    Sensor

    PT100 (platinum resistance)

    Control mode

    Anti integral saturation PID+self-tuning

    Communication function

    (Optional feature) RS485, convenient for remote and local communication monitoring, (requires monitoring software, RS485/RS232 converter, requires 1 PC COM and 1 USB port each), can connect up to 16 units at the same time, with a maximum cable length of 70am

    Additional features

    Fault alarm prompt function, upper and lower limit protection function

    Applicable power supply (V)

    AC voltage 380V ± 38V frequency 50Hz ± 0.5Hz three-phase four wire+grounding protection

    Maximum current (A) 3 4 7.6 9.8 4.1 5.8 9.8 14.5
    Power Supply (kW) 2 2.7 5 6.5 2.7 3.8 6.5 9.5
    Weight (kg) 120 160 280 460 120 160 280 460

    Standard configuration

    2 sets of sample shelf, 4 casters, 4 fuses, 1 set of oxygen concentration analyzer, 3 flow meters, 2 pressure reducing valves, and 1 fan gearbox

    Safety device

    Leakage switch, motor, compressor, phase sequence, over temperature and other protection functions

    Note: The nitrogen intake pressure and air intake pressure are both 1kgf/cm²