number
Anaerobic high temperature test chamber
Retail price
Market price
key word:humidity
weight
inventory
隐藏域元素占位
- Advisory Details
-
Product name
Anaerobic high temperature test chamber
Model
YY91-200 YY216-200 YY512-200 YY1000-200 YY91-300 YY216-300 YY512-300 YY1000-300 Interior volume (L)
91 216 512 1000 91 216 512 1000 Inside dimension
(mm)
W
450 600 800 1000 450 600 800 1000 H
450 600 800 1000 450 600 800 1000 D
450 600 800 1000 450 600 800 1000 Outside dimension (mm)
W
1060 1210 1500 1730 1060 1210 1500 1730 H
820 970 1210 1480 820 970 1210 1480 D
635 785 1065 1270 635 785 1065 1270 Temperature range (℃) (ambient temperature+20~200)℃ (ambient temperature+20~300)℃ Heating and cooling time (min) (ambient temperature+20~200)℃ (ambient temperature+20~300)℃ ≤40/min ≤60/min ≤70/min Residual oxygen concentration<100ppm, flow rate of pure inert gas (such as N2) consumed ≤ 20L/min (reduced to ≤ 50min) ≤ 50L/min (reduced to ≤ 50min) ≤ 100L/min (reduced to ≤ 50min) ≤ 200L/min (reduced to ≤ 50min) ≤ 7L/min (concentration maintained) ≤ 15L/min (concentration maintained) ≤ 30L/min (concentration maintained) ≤ 60L/min (concentration maintained) Temperature regulation method Forced air circulation heat exchange method+internal cooling system Usage environment Temperature: (5~36) ℃ Humidity: (30~85)%RH Air pressure: (86~106) kPa Material Science Inner box
Stainless steel plate SUS304
Outer box
Double sided galvanized sheet, surface treated with electrostatic spraying treatment Heat preservation Fiber high-temperature cotton+polyurethane foam
Box door sealing strip High temperature resistant sealing strip (excluding silicon) Actuator Fan
Extended shaft centrifugal fan Damper
Manually adjust ventilation and circulation
Heater
Imported nickel chromium alloy electric heating wire Controller system Display screen+PLC
7.0", 800x480 resolution, mixed output PLC Operation mode
Program execution
Setting method
Simplified Chinese+English, touch input
Display resolution
Temperature: 0.1 ℃, Time: s
Sensor
PT100 (platinum resistance)
Control mode
Anti integral saturation PID+self-tuning Communication function
(Optional feature) RS485, convenient for remote and local communication monitoring, (requires monitoring software, RS485/RS232 converter, requires 1 PC COM and 1 USB port each), can connect up to 16 units at the same time, with a maximum cable length of 70am Additional features
Fault alarm prompt function, upper and lower limit protection function
Applicable power supply (V)
AC voltage 380V ± 38V frequency 50Hz ± 0.5Hz three-phase four wire+grounding protection
Maximum current (A) 3 4 7.6 9.8 4.1 5.8 9.8 14.5 Power Supply (kW) 2 2.7 5 6.5 2.7 3.8 6.5 9.5 Weight (kg) 120 160 280 460 120 160 280 460 Standard configuration
2 sets of sample shelf, 4 casters, 4 fuses, 1 set of oxygen concentration analyzer, 3 flow meters, 2 pressure reducing valves, and 1 fan gearbox
Safety device
Leakage switch, motor, compressor, phase sequence, over temperature and other protection functions
Note: The nitrogen intake pressure and air intake pressure are both 1kgf/cm²
Related products