- Advisory Details
-
Product name
Cold and thermal shock test box (three boxes) Model
TS3z-
70-40W
TS3z-
150-40W
TS3z-
200-40W
TS3z-
300-40W
TS3z-
70-55W
TS3z-
150-55W
TS3z-
200-55W
TS3z-
300-55W
TS3z-
70-65W
TS3z-
150-65
TS3z-
200-65W
TS3z-
300-65W
Interior volume (L)
70
150
200
300
70
150
200
300 70
150
200
300
Inside dimension
(mm)
W
410
650
650
970
410
650
650
970
410
650
650
970
H
460
460
460
460
460
460
460
460
460
460
460
460
D
370
500
670
670
370
500
670
670
370
500
670
670
Outside dimension (mm)
W
1470
1710
1710
2030
1470
1710
1710
2030
1470
1710
1710
2030
H
1860
1860
1860
1860
1860
1860
1860
1860
1860
1860
1860
1860
D
1870
1700
1870
1870
1870
1700
1870
1870
1870
1700
1870
1870
Maximum weight of sample (kg)
2.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8 2.8
7.8
7.8
7.8
Test method
Pneumatic door switches between high and low temperature zones
Pre heating and pre cooling temperature
Pre heating: (60~200) ℃ Pre cooling: (-80~0) ℃
Temperature recovery/switching time
Recovery time: 5min Switching time: ≤ 10s
Temperature deviation (℃)
±2. 0℃
Exposure time
High temperature exposure: 30min Low temperature exposure: 30min
Weight (kg)
980
1050
1400
1500
1400
1450
1480
1510 1430
1480
1680
1790
Maximum current (A)
40
45
60
60
59
59
63
63 63
63
85
95
Power Supply(KW)
26
29
37
37
37
37
38
38 38
38
53
58
Circulating cooling water(t/h)
2.8
3
3
3
5
5
6
6 8
10
15
15
Material Science
Inner box
Stainless steel plate SUS304
Outer box
Double sided galvanized sheet, surface treated with electrostatic spraying treatment
Heat preservation
Fiber high-temperature cotton+polyurethane foam
Actuator
High temperature tank
Heater: Nickel chromium alloy heating wire
High temperature impact fan, use axial flow fan for preheating
Low temperature tank
Heater: Nickel alloy heating wire accumulator: Sheet aluminum plate
Fan: Low temperature resistant fan
Wind door drive
Pneumatic cylinder: used to drive the air door during high and low temperature, and normal temperature impact
Air compressor: purpose of gas supply
Refrigeration system
Refrigeration method: low-noise piston compressor+binary cascade refrigeration
Refrigerant: Environmentally friendly refrigerant R404A R23
Controller system
Touch screen+PLC
7.0 "or 10.0", 800x480 resolution, mixed output PLC
Operation mode
Program running, timed running
Setting method
Simplified Chinese+English, touch input
Program capacity
100 sets of programs, with a maximum of 100 segments per set, capable of 999 loops, and programs with linking function
Set Range
Adjust ± 5.0 ℃ based on the maximum range of equipment performance
Display resolution
Temperature: 0.1 ℃, Time: s
Sensor
PT100 (platinum resistance)
Control mode
Low temperature cold balance +anti integral saturation PID+self-tuning
Curve recording
Equipped with live data storage function, the screen can slide to browse data and capture images
Additional features
Fault alarm and cause handling prompt function: timed power on/off, power-off protection, user permission function
Communication function
Support RS485, LAN (network port), convenient for remote monitoring, data collection: IBM PC compatible machine, PII or above CPU, 128MB or above memory, Simplified Chinese version operating system Data acquisition
1. It has a USB interface that can save curve data for 3 months, and can download historical curves and data;
2 can replace the recorder, with built-in large storage space. It can save data for 3 months after 24 hours of continuous startup, with a sampling time of 1 minute. It can replace computer storage, and users can export historical data from a USB flash drive (time optional) to generate CSV format files;
3. Connect to PC (optional) - Record test data through computer monitoring software, display curves, and use PC as a remote terminal to achieve remote monitoring.
Compressed air
Pressure: 0.5~0.7MPa Flow rate: 0.1m ³/min
Circulating cooling water
Water pressure: 0.25~0.4MPa Water temperature: ≤30℃
Applicable power supply (V)/(Hz)
AC voltage 380V ± 38V frequency 50Hz ± 0.5Hz three-phase four wire+grounding protection
Standard configuration
1 cable port (ф50mm), 2 sets of sample shelf, and 4 casters
Safety device
Leakage switch, motor, compressor, phase sequence, over temperature and other protection functions
Related products