number
High temperature test chamber
Retail price
Market price
key word:humidity
weight
inventory
隐藏域元素占位
- Advisory Details
-
Product name
High temperature test chamber
Model
YB91-200N YB216-200N YB512-200N YB1000-200N YB91-300N YB216-300N YB512-300N YB1000-300N Interior volume (L)
91 216 512 1000 91 216 512 1000 Inside dimension
(mm)
W
450 600 800 1000 450 600 800 1000 H
450 600 800 1000 450 600 800 1000 D
450 600 800 1000 450 600 800 1000 Outside dimension (mm)
W
1060 1210 1500 1730 1060 1210 1500 1730 H
820 970 1210 1480 820 970 1210 1480 D
635 785 1065 1275 635 785 1065 1275 Temperature range (℃) (ambient temperature+20~200) ℃ (ambient temperature+20~300) ℃ Temperature fluctuation ≤100℃
±0.2℃ ±0.3℃ ±0.3℃ ±0.3℃ ≤200℃ ±0.2℃ ±0.4℃ ±0.3℃ ±0.4℃ ≤300℃
— — ±0.4℃ ±0.6℃ Temperature deviation ≤100℃
±1.5℃ ±2℃ ±1.5℃ ±2℃ ≤200℃ ±2.0℃ ≤300℃
— ±3.0℃ ±3.0℃ Heating time (min) (ambient temperature+20~200) ℃ (ambient temperature+20~300) ℃ ≤40/min ≤60/min ≤70/min Temperature regulation method
Forced air circulation heat exchange method Usage environment Temperature: (5~36) ℃ Humidity: (30~85)% RH Pressure: (86~106) kPa Material Science
Inner box
Stainless steel plate SUS304
Outer box
Double sided galvanized sheet, surface treated with electrostatic spraying treatment
Heat preservation
Fiber high-temperature cotton
Actuator
Fan
Extended shaft centrifugal fan
Damper Manually adjust ventilation and circulation
Heater
Imported nickel chromium alloy electric heating wire
Controller system
Display
7.0",800x480 resolution, mixed output PLC Operation mode
Fixed value running, program running
Setting method
English, key input
Display resolution
Temperature: 0.1 ℃, Time: min
Sensor
PT100 (platinum resistance) Control mode
Anti integral saturation P1D+self-tuning
Communication function
(Optional function) RS485, convenient for remote and local communication monitoring, (requires monitoring software, RS485/RS232 converter, requires one COM and one USB port for PC), can connect up to 16 units at the same time, with a maximum cable length of 700m Supplementary functions
Fault alarm function, upper and lower limit protection function Applicable power supply (V)
AC voltage 380V ± 38V frequency 50Hz ± 0.5Hz three-phase four wire+grounding protection
Maximum current (A)
3 4 7.6 9.8 4.1 5.8 9.8 14.5 Power (KW)
2 2.7 5 6.5 2.7 3.8 6.5 9.5 Weight (kg) 95 130 240 430 95 130 240 430 Standard configuration
1 on each side of the cable port (ф50mm) and 2 sets of sample shelf
Safety device
Leakage switch, motor, compressor, phase sequence, over temperature, dry burning and other protection functions
Related products
资料下载