  • 步入式1.png
  • 步入式2.png
  • 步入式3.png

number

Walk-in constant temperature and humidity test room(aging room)


Retail price

Market price


Walk-in constant temperature and humidity test room(aging room)

key word:humidity

Consultation hotline:

weight

Quantity
-
+

inventory

隐藏域元素占位

  • Advisory Details
  • Product name

    Walk-in constant temperature and humidity test room(aging room)
    Model YW
    078-40WX5LH

    YW

    117-40WX5LH

    YW

    156-40WX5LH

    YW

    162-40WX5LH

    YW

    216-40WX5LH

    YW

    270-40WX5LH

    YW

    220-40WX5LH

    YW

    294-40WX5LH

    YW

    367-40WX5LH

    YW

    441-40WX5LH

    Interior volume (L) 6.8/7.8 10.2/11.7 13.6/15.6 14.2/16.2 18.9/21.6 23.6/27 19.36/22 25.7/29.4 32.2/36.7 38.6/44.1
    Inside dimension (mm)

    W

    1800 2500 3400

    H

    L-type: 2100/H-type: 2400

    D

    1800 2700 3600 2700 3600 4500 2700 3600 4500 5400

    Outside dimension (mm)

    W

    2000 2000 2000 2000 2700 2700 3600 3600 3600 3600

    H

    L-type: 2400/H-type: 2700

    D

    Inner dimension D+1205 Inner dimension D+1355 Inner dimension D+1650
    Performance Temperature range (℃) Minimum temperature: -10 ℃,-20 ℃, -30 ℃, -40 ℃, -50 ℃, -60 ℃, -65 ℃, maximum temperature:+85 ℃

    Humidity range

     (% RH)

    (20~98)%RH(20~85)℃
    Temperature fluctuation (℃) ±0.5℃
    Temperature deviation (℃) ±2. 0℃
    Humidity deviation (% RH) ±3.0%RH(>75%RH)±5.0%RH(≤75%RH)
    Heating time (25~85)℃
    ≤45min ≤50min ≤55min ≤45min ≤50min ≤60min ≤50min ≤60min ≤70min ≤80min
    Cooling time 25 ℃~rated extreme low temperature
    (30~180) min (varies depending on different models and configurations)
    Temperature and humidity regulation method BTHC Balanced Temperature Control (SSR Humidity Control) Method
    Usage environment Temperature: (5~36) ℃ Humidity: (30~85)% RH Pressure: (86~106) kPa
    Thermal insulation board structure Spray coated galvanized color steel plate - attached temperature stress insulation material - SUS304 stainless steel composite assembly plate

    Actuator

    Fan

    Extended shaft centrifugal fan

    Refrigerator

    Low noise piston compressor or scroll compressor

    Heater

    Imported nickel chromium alloy electric heating wire
    Humidifier 316 stainless steel humidifier (external steam generator)
    Controller system Touch screen+PLC 7.0"or 10.0", 800X480 resolution, mixed output PLC
    Operation mode Fixed value running, program running, timed running
    Setting method Simplified Chinese+English, touch input
    Program capacity 100 sets of programs, with a maximum of 100 segments per set, capable of 999 loops, and programs with linking function
    Set Range Adjust ± 5.0 ℃ and humidity range (5~100)% RH (humidity equipment) based on the maximum range value of equipment performance
    Display resolution Temperature: 0.01 ℃, Humidity: 0.1%RH (humidity equipment), Time: s

    Sensor

    PT100 (platinum resistance)
    Control mode Low temperature cold balance+anti integral saturation PID+self-tuning
    Curve recording Equipped with live data storage function: can slide and browse data on the screen: capture function
    Additional features Fault alarm and cause handling prompt function: timed power on/off, power-off protection, user permission function
    Communication function Support RS485, LAN (network port), convenient for remote monitoring, data collection: IBM PC compatible machine, PII or above CPU, 128MB or above memory, Simplified Chinese version operating system
    Data acquisition

    1. Equipped with US8 interface, it can save curve data for 3 months and download historical curves and data;

    2. It can replace a recorder, with a built-in large storage space that can save data for 3 months after 24 hours of continuous startup. The sampling time is minutes, and it can replace computer storage. Users can export historical data from a USB flash drive (time optional) and generate CSV format files;

    3. Connect to PC (optional) - Record test data through computer monitoring software, display curves, and use PC as a remote terminal to achieve remote monitoring.

    Water supply Water supply system Equipped with multi-stage filtration reverse osmosis pure water machine or water pump lift
    Water Quality Electric positive rate>500Ω
    Circulating cooling water Water supply pressure: 0.25~0.4MPa Water temperature: ≤ 30℃
    Applicable power supply (V) AC voltage 380V ± 38V frequency 50Hz ± 0.5Hz three-phase four wire+grounding protection
    Applicable power supply(KW) (20~55) kW (varies depending on different models and configurations)
    Standard configuration 1 electric heating observation window, 1 on each side of the cable port (ф50mm), 2 sets of sample shelf, and 4 casters
    Safety device Leakage switch, motor, compressor, phase sequence, over temperature, burning and other protection functions

The previous

next

资料下载

Request a quotation

*
*
*
*
*