number
Cold and thermal shock test box (two boxes)
Retail price
Market price
key word:humidity
weight
inventory
隐藏域元素占位
- Advisory Details
-
Product name
Cold and thermal shock test box (two boxes) Model
Ts2z-
60-40W
Ts2z-
125-40W
Ts2z-
200-40W
Ts2z-
300-40W
Ts2z-
60-55W
Ts2z-
125-55W
Ts2z-
200-55W
Ts2z-
300-55W
Ts2z-
60-65W
Ts2z-
125-65W
Ts2z-
200-65W
Ts2z-
300-65W
Interior volume (L)
60
125
200
300
60
125
200
300
60 125 200 300 Inside dimension
(mm)
W
400
470
770
770
400
470
770
770
400 470 770 770 H
370
410
610
610
370
410
610
610
370 410 610 610 D
430
650
450
650
430
650
450
650
430 650 450 650 Outside dimension (mm)
W
860
875
1190
1190
860
875
1190
1470
860 875 1190 1470 H
2000
2000
2400
2400
2000
2000
2400
2200
2000 2000 2400 2200 D
2050
2250
2250
2450
2050
2250
2250
2500
2050 2250 2250 2500 Maximum weight of sample (kg)
20
50
70
80
20
50
70
80
20 50 70 80 Test method
Sample area basket lifting or lowering Pre heating and pre cooling temperature
Pre heating: (60~185) ℃ Pre cooling: (-80~5) ℃
Temperature recovery/switching time
Recovery time: 2~5min Switching time: ≤ 10s
Temperature deviation (℃)
±2. 0℃
Exposure time
High temperature exposure :30min Low temperature exposure :30min Weight (kg)
880
950
1100
1300
910
980
1300
1500
950 1100 1500 1700 Maximum current A)
30
42
47
52
42
42
55
65
47 47 65 72 Power Supply (KW)
20
20
25
30
23
23
34
45
26 26 45 55 Circulating cooling water (t/h)
4
5
7
9
7
8
9
13
9 10 14 16 Material Science
Inner box
Stainless steel plate SUS304 Outer box
Double-sided galvanized steel plate, electrostatic spray after surface treatment Heat preservation
Fiber high temperature cotton + polyurethane foam Actuator
High temperature tank
Heater: Nickel chromium alloy heating wire
High temperature impact fan, use axial flow fan for preheating
Low temperature tank
Heater: Nickel alloy heating wire accumulator: Sheet aluminum plate
Fan: Low temperature resistant fan
Basket drive Electric lead screw: Used for moving the basket up and down in the sample area Motor drive (380V) Refrigeration system
Refrigeration method: low-noise piston compressor+binary cascade refrigeration
Refrigerant: Environmentally friendly refrigerant R404A,R23
Controller system
Touch screen+PLC
7.0 "or 10.0", 800x480 resolution, mixed output PLC
Operation mode
Program running, timed running
Setting method
Simplified Chinese+English, touch input
Program capacity
96 sets of programs, each consisting of 3 segments, capable of 32000 loops, with linking functionality Set Range
Adjust ±5.0℃ based on the maximum range of device performance Display resolution
Temperature: 0.1 ℃, Time: s
Sensor
PT100 (platinum resistance)
Control mode
Low temperature cold balance+anti integral saturation PID+self-tuning
Curve recording
Equipped with live data storage function, the screen can slide to browse data and capture images
Additional features
Fault alarm and cause handling prompt function: timed power on/off, power-off protection, user permission function
Communication function
Support RS485, LAN (network port), convenient for remote monitoring, data collection: IBM PC compatible machine, PII or above CPU, 128MB or above memory, Simplified Chinese version operating system Data acquisition
1. It has a USB interface that can save curve data for 3 months, and can download historical curves and data;
2 can replace the recorder, with built-in large storage space. It can save data for 3 months after 24 hours of continuous startup, with a sampling time of 1 minute. It can replace computer storage, and users can export historical data from a USB flash drive (time optional) to generate CSV format files;
3. Connect to PC (optional) - Record test data through computer monitoring software, display curves, and use PC as a remote terminal to achieve remote monitoring.
Compressed air
Pressure: 0.5~0.7MPa Flow rate: 0.1m ³/min
Circulating cooling water
Water pressure: 0.25~0.4MPa Water temperature: ≤30℃
Applicable power supply (V)/(Hz)
AC voltage 380V ± 38V frequency 50Hz ± 0.5Hz three-phase four wire+grounding protection Standard configuration
One cable port (ф50mm), two sets of sample shelf, and four casters
Safety device
Leakage switch, motor, compressor, phase sequence, over temperature and other protection functions
Related products
资料下载
Request a quotation