number
High and low temperature humidity test chamber
Retail price
Market price
key word:humidity
weight
inventory
隐藏域元素占位
- Advisory Details
-
Product name
High and low temperature humidity test chamber Model
FP TH
64-20A
FP TH
225-20A
FP TH
420-20A
FP TH
1000-20A
FP TH
64一40A
FP TH
225-40A
FP TH
420-40A
FP TH
1000-40A
FP TH
64-70A
FP TH
225-70A
FP TH
420-70A
FP TH
1000-70A
Interior volume (L)
64 225 420 1000 64 225 420 1000 64 225 420 1000 Inside dimension (mm) W
400 700 700 1000 400 700 700 1000 400 700 700 1000 H
400 700 750 1000 400 700 750 1000 400 700 750 1000 D
400 500 800 1000 400 500 800 1000 400 500 800 1000 Outside dimension (mm)
W
600 900 900 1200 600 900 900 1200 600 900 900 1200 H
1410 1930 1990 2240 1410 1930 1990 2240 1410 1930 1990 2240 D
1120 1440 1840 2040 1120 1440 1840 2040 1120 1440 1840 2040 Temperature range (℃) -20~150 -40~150 -70~150 Humidity range (% RH) (20~98)%RH(20~85)℃ Temperature fluctuation (℃) ±0.5℃ Temperature deviation (℃) ±2℃ Humidity deviation (% RH) ±3.0%RH(>75%RH) ±5.0%RH(<75%RH) Heating time -20~150℃ -40~150℃ -70~150℃ ≤35min ≤40min ≤55min ≤60min ≤35min ≤40min ≤55min ≤60min ≤45min ≤45min ≤60min ≤80min Cooling time
+20~20℃ +20~40℃ +20~70℃ ≤40min ≤40min ≤40min ≤40min ≤60min ≤60min ≤60min ≤60min ≤80min ≤80min ≤80min ≤80min Temperature and humidity regulation method BTHC Balanced Temperature Control (SSR Humidity Control) Method Usage environment Temperature: (5~36) ℃ Humidity: (30~85)% RH Pressure: (86~106) kPa Material Science
Inner box Stainless steel plate SUS304
Outer box Double sided galvanized sheet, surface treated with electrostatic spraying treatment
Heat preservation
Fiber high-temperature cotton+polyurethane foam
Actuator
Fan
Extended shaft centrifugal fan
Compressor Low noise piston compressor or scroll compressor
Heater
Imported nickel chromium alloy electric heating wire
Humidifier 316 stainless steel humidifier (external steam generator) Controller system
Touch screen+PLC
LED screen
Operation mode
Fixed value running, program running
Setting method
English, key input
Program capacity 100 sets of programs, with a maximum of 100 segments per set, capable of 999 loops, and programs with linking function Set Range Adjust the maximum temperature range of ± 5.0 ℃ and humidity range 5~ 100%RH (humidity equipment) based on the performance of the device Display resolution
Temperature: 0.1 ℃, Time: mins
Sensor
PT100 (platinum resistance)
Control mode
Low temperature cold balance+anti integral saturation PID+self-tuning
Curve recording Equipped with live data storage function, the screen can slide to browse data and capture images Additional features Fault alarm and cause handling prompt function: timed power on/off, power-off protection, user permission function Communication function
Support RS485, LAN (network port), convenient for remote monitoring, data collection: IBM PC compatible machine, PII or above CPU, 128MB or above memory, Simplified Chinese version operating system Data acquisition
1. Equipped with a USB interface, it can save curve data for 3 months and download historical curves and data;
2. It can replace a recorder with a built-in large storage space. It can save data for 3 months when turned on continuously for 24 hours, with a sampling time of 1 minute. It can replace computer storage and users can export historical data using a USB flash drive (time optional). Generate CSV format files;
3. Connect to PC (optional) - Record test data through computer monitoring software, display curves, and use PC as a remote terminal to achieve remote monitoring.
Water supply
Water supply method
Pump pumping Water storage tank
10L/20L/40L Water Quality
Electrical resistivity>500 Ω Circulating water flow rate (t/h) 0.4 0.5 0.5 0.6 0.4 0.5 0.6 1 0.4 0.5 1 1.2 Power supply (V) AC voltage 380V ± 38V frequency 50M ± 0.5Hz three-phase four wire+grounding protection
Maximum current (A)
10 13 14 24 10 13 14 25 13 18 21 38 Power (KW)
4 6 6 11 4.5 6.5 7 12 5 8 12 18 Weight Kg 145 200 530 760 145 205 540 800 165 245 600 900 Standard configuration
1 electric heating observation window, 1 on each side of the cable port (ф50mm), 2 sets of sample shelf, and 4 casters
Safety device
Leakage switch, motor, compressor, phase sequence, over temperature, dry burning and other protection functions
A,Hindicates the presence of humidity function. b.c,This option is only available for damp heat test chambers. d,Select the loop water cooling option.
Note: 1. A represents fresh air cooling, W represents circulating water cooling. 2. Freezing point series test chambers can be customized according to customer needs.
Related products
资料下载
Request a quotation