  • 恒温恒湿试验箱.png

number

High and low temperature humidity test chamber


Retail price

Market price


High and low temperature humidity test chamber

key word:humidity

Consultation hotline:

weight

Quantity
-
+

inventory

隐藏域元素占位

  • Advisory Details
  • Product name

    High and low temperature humidity test chamber

    Model

    FP TH

    64-20A

    FP TH

    225-20A

    FP TH

    420-20A

    FP TH

    1000-20A

    FP TH

    64一40A

    FP TH

    225-40A

    FP TH

    420-40A

    FP TH

    1000-40A

    FP TH

    64-70A

    FP TH

    225-70A

    FP TH

    420-70A

    FP TH

    1000-70A

    Interior volume (L)

    64 225 420 1000 64 225 420 1000 64 225 420 1000
    Inside dimension (mm)

    W

    400 700 700 1000 400 700 700 1000 400 700 700 1000

    H

    400 700 750 1000 400 700 750 1000 400 700 750 1000

    D

    400 500 800 1000 400 500 800 1000 400 500 800 1000

    Outside dimension (mm)

    W

    600 900 900 1200 600 900 900 1200 600 900 900 1200

    H

    1410 1930 1990 2240 1410 1930 1990 2240 1410 1930 1990 2240

    D

    1120 1440 1840 2040 1120 1440 1840 2040 1120 1440 1840 2040
    Temperature range (℃) -20~150 -40~150 -70~150
    Humidity range (% RH) (20~98)%RH(20~85)℃
    Temperature fluctuation (℃) ±0.5℃
    Temperature deviation (℃) ±2℃
    Humidity deviation (% RH) ±3.0%RH(>75%RH)  ±5.0%RH(<75%RH)
    Heating time -20~150℃ -40~150℃ -70~150℃
    ≤35min ≤40min ≤55min ≤60min ≤35min ≤40min ≤55min ≤60min ≤45min ≤45min ≤60min ≤80min

    Cooling time

    +20~20℃ +20~40℃ +20~70℃
    ≤40min ≤40min ≤40min ≤40min ≤60min ≤60min ≤60min ≤60min ≤80min ≤80min ≤80min ≤80min
    Temperature and humidity regulation method BTHC Balanced Temperature Control (SSR Humidity Control) Method
    Usage environment Temperature: (5~36) ℃ Humidity: (30~85)% RH Pressure: (86~106) kPa

    Material Science

    Inner box

    Stainless steel plate SUS304

    Outer box

    Double sided galvanized sheet, surface treated with electrostatic spraying treatment

    Heat preservation

    Fiber high-temperature cotton+polyurethane foam

    Actuator

    Fan

    Extended shaft centrifugal fan

    Compressor

    Low noise piston compressor or scroll compressor

    Heater

    Imported nickel chromium alloy electric heating wire

    Humidifier 316 stainless steel humidifier (external steam generator)

    Controller system

    Touch screen+PLC

    LED screen

    Operation mode

    Fixed value running, program running

    Setting method

    English, key input

    Program capacity 100 sets of programs, with a maximum of 100 segments per set, capable of 999 loops, and programs with linking function
    Set Range Adjust the maximum temperature range of ± 5.0 ℃ and humidity range 5~ 100%RH (humidity equipment) based on the performance of the device

    Display resolution

    Temperature: 0.1 ℃, Time: mins

    Sensor

    PT100 (platinum resistance)

    Control mode

    Low temperature cold balance+anti integral saturation PID+self-tuning

    Curve recording Equipped with live data storage function, the screen can slide to browse data and capture images
    Additional features Fault alarm and cause handling prompt function: timed power on/off, power-off protection, user permission function

    Communication function

    Support RS485, LAN (network port), convenient for remote monitoring, data collection: IBM PC compatible machine, PII or above CPU, 128MB or above memory, Simplified Chinese version operating system

    Data acquisition

    1. Equipped with a USB interface, it can save curve data for 3 months and download historical curves and data;

    2. It can replace a recorder with a built-in large storage space. It can save data for 3 months when turned on continuously for 24 hours, with a sampling time of 1 minute. It can replace computer storage and users can export historical data using a USB flash drive (time optional). Generate CSV format files;

    3. Connect to PC (optional) - Record test data through computer monitoring software, display curves, and use PC as a remote terminal to achieve remote monitoring.

    Water supply

    Water supply method

    Pump pumping

    Water storage tank

    10L/20L/40L

    Water Quality

    Electrical resistivity>500 Ω
    Circulating water flow rate (t/h) 0.4 0.5 0.5 0.6 0.4 0.5 0.6 1 0.4 0.5 1 1.2
    Power supply (V)

    AC voltage 380V ± 38V frequency 50M ± 0.5Hz three-phase four wire+grounding protection

    Maximum current (A)

    10 13 14 24 10 13 14 25 13 18 21 38

    Power (KW)

    4 6 6 11 4.5 6.5 7 12 5 8 12 18
    Weight Kg 145 200 530 760 145 205 540 800 165 245 600 900

    Standard configuration

    1 electric heating observation window, 1 on each side of the cable port (ф50mm), 2 sets of sample shelf, and 4 casters

    Safety device

    Leakage switch, motor, compressor, phase sequence, over temperature, dry burning and other protection functions

    A,Hindicates the presence of humidity function. b.c,This option is only available for damp heat test chambers. d,Select the loop water cooling option.

    Note: 1. A represents fresh air cooling, W represents circulating water cooling. 2. Freezing point series test chambers can be customized according to customer needs.